A/V · Lighting · HVAC · Security
Residential systems
Home theaters through whole-house automation, including cameras, gate and door access, and pool and spa.
Crestron Services Provider
Home control systems that are simple to use and dependable, programmed with the discipline of a career software engineer. Based in San Diego County, California.
New systems, changes to existing ones, and support for the systems One Step Logic has programmed.
A/V · Lighting · HVAC · Security
Home theaters through whole-house automation, including cameras, gate and door access, and pool and spa.
Layouts · Custom graphics
Clean, consistent screens that people understand at a glance, with custom graphics when a project calls for them.
SIMPL+ · RS-232 · RS-485 · TCP/IP
Modules and protocols for devices Crestron doesn't support yet, for integrators and hardware manufacturers.
Updates · Fixes · Rewrites
Changes and fixes to programs, including ones written by someone else. If the source is lost, the system can be reprogrammed.
Troubleshooting · Changes
Continued support for systems One Step Logic has programmed, as needs and equipment change.
The same four steps for a new system, a custom module or changes to an existing program.
Send the scope, the equipment list with model numbers, any drawings, and what the system needs to do.
A detailed estimate of what will be built and how it will work. Work starts once you approve it.
The control program, touch panels and any custom modules, built and tested to the approved scope.
Defects fixed at no charge for six months (twelve for custom modules), and your source code on request once the project is paid.
Dorel Zamfir founded One Step Logic after a career as a software engineer, from embedded systems to desktop applications, in the health care, communications and manufacturing industries, and four years programming in the U.S. Air Force.
That background shows in the work: structured, well-tested programs that are easy to extend later, and modules that talk to hardware reliably.
// Excerpt of a device module (example)
#SYMBOL_NAME "Projector Control"
#DEFAULT_VOLATILE
DIGITAL_INPUT Power_On, Power_Off;
STRING_INPUT From_Device$[255];
STRING_OUTPUT To_Device$;
ANALOG_OUTPUT Lamp_Hours;
PUSH Power_On
{
To_Device$ = "PWR ON\r";
}
CHANGE From_Device$
{
IF (Find("LAMP=", From_Device$))
Lamp_Hours = Atoi(From_Device$);
}
Email for support, changes or additions to your system.
Send a short description: the scope, the equipment list with model numbers, and what the system needs to do. You'll hear back whether it's a good fit.